Used to reject application-level messages that cannot be rejected by other means
From the TT FIX Order Gateway to a third-party FIX acceptor and from a third-party FIX acceptor to TT FIX Order Gateway
Tag # | Field Name | Req’d | Data type | Comments | |
---|---|---|---|---|---|
Component Block <Standard Header> | Y | 35=j (MsgType) | |||
45 | RefSeqNum | Y | int |
Value of Tag 34 (MsgSeqNum) in the rejected message |
|
372 | RefMsgType | Y | string |
Value of Tag 35 (MsgType) in the rejected message |
|
379 | BusinessRejectRefID | C | string |
Value of the business-level ID field in the referenced message Maximum length: 63 characters Condition: Sent when the rejected message contains an ID |
|
380 | BusinessRejectReason | Y | int |
Reason for the rejecting the message Possible values include:
|
|
58 | Text | N | string |
Text description of the reason for the rejection |
|
Component Block <Standard Trailer> | Y |
The Business Message Reject (j) message is used by the TT FIX Order Gateway or third party FIX acceptor whenever it rejects an application-level message that fulfills session-level rules but cannot be rejected via any other means (i.e. Order Cancel Reject (9) message).
Any application-level message